The products are mainly used to control switching on/off of power supply of storage battery car, electric forklift, electric winch, electric car, excavator, air conditioner in vehicle
InquiryApplication
The products are mainly used to control switching on/off of power supply of storage battery car, electric forklift, electric winch, electric car, excavator, air conditioner in vehicle, power source
Ordering Notice
For example: ZJWT200DE/12V
The DC contactor of main contact is commutation, rated voltage not more than DC48V, current 200A,
Basic Technical Parameters (at normal conditions) | |||
Electric Parameters | |||
Contact type | A set of commutation contacts | Instantaneous maxi (closing) current | 7Ie,≤1s |
Rated voltage of contacts (DC) | ≤48V | Insulation resistance(MΩ) | ≥100 |
Rated current of contacts (A) | 200 | Dielectric withstand voltage | 1500V,p.f. 1min, no breakdown |
Voltage drop on contacts(mV) | ≤100 | Electric cycles (104) | ≥2 |
Coil voltage specification(DC) | 12V, 24V, 48V, 72V etc | Mechanical cycles (104) | ≥30 |
DC power consumption of coil (W) | ≤20W | Temperature rise on outgoing terminal | ≤65 |
Pickup voltage(DC) | ≤70%Us | Temperature rise of coil(K) | ≤85 |
Release voltage(DC) | ≥5%Us;≤40%Us | Insulation grade of enameled wire | Class B (130°C) |
Pickup time(ms) | ≤50 | Material of contact | AgCuO(10)/Cu |
Release time(ms) | ≤50 | Working duty | Continuous operating duty |
Mechanical/Ambient Conditions | |||
Torque of outgoing terminal on contact M8(N.m) |
≯9.0N appropriate | Protection grade | IP50 |
Coil wiring insert(mm) | ≯0.8 | Mounting methods | Freely |
Working temperature | (-25~+55)°C | Vibration | Sine shock: 2.5g, (5~50) Hz |
Mounting altitude | ≤2Km | Impact | 50g,11ms(Half sine) |
Conversion Table for Coil Specification(20°C) | |||
Voltage(V) | Coil resistance(1±10%)Ω | Voltage(V) | Coil resistance(1±10%)Ω |
12 | 7.2 | 60 | 180 |
24 | 28.8 | 72 | 259.2 |
48 | 115.2 | 80 | 320 |
Outline and Mounting Picture